RTE France

ADNLimitReductionsParameters

ADNLimitReductionsParameters

The ADNLimitReductionsParameters class is used to model limit reductions for a given voltage range (inclusive). It contains a coefficient for permanent limits and a list of coefficients for temporary limits.

Optional properties

maxVoltage

The maxVoltage property is an optional property that defines the upper bound of the [minVoltage, maxVoltage] range. The default value of this property is Float.MAX_VALUE.

minVoltage

The minVoltage property is an optional property that defines the lower bound of the [minVoltage, max] range. The default value of this property is 0.

permanent

The permanent property is an optional property that define the limit reduction for permanent limits. The default value of this property is 1 (e.g. 100%).

temporaries

The temporaries property is an optional property that defines the temporary limits reductions, model by the ADNTemporaryLimitsParameters class.

ADNTemporaryLimitParameters

The com.rte_france.powsybl.iidm.export.adn.ADNTemporaryLimitParameters class is used to model limit reductions for temporary limits in a given duration range (inclusive).

Optional properties

maxDuration

The maxDuration property is an optional property that defines the upper bound of the [minDuration, maxDuration] range. The default value of this property is Integer.MAX_VALUE.

minDuration

The minDuration property is an optional property that defines the lower bound of the [minDuration, maxDuration] range. The default value of this property is 0.

reduction

THe reduction property is an optional property that defines the limit reduction for temporary limits. The default value of this property is 1 (e.g. 100%).