ADNLimitReductionsParameters
The ADNLimitReductionsParameters class is used to model limit reductions for a given voltage range (inclusive). It contains a coefficient for permanent limits and a list of coefficients for temporary limits.
Optional properties
maxVoltage
The maxVoltage
property is an optional property that defines the upper bound of the [minVoltage, maxVoltage] range. The
default value of this property is Float.MAX_VALUE
.
minVoltage
The minVoltage
property is an optional property that defines the lower bound of the [minVoltage, max] range. The
default value of this property is 0.
permanent
The permanent
property is an optional property that define the limit reduction for permanent limits. The default value
of this property is 1 (e.g. 100%).
temporaries
The temporaries
property is an optional property that defines the temporary limits reductions, model by the
ADNTemporaryLimitsParameters
class.
ADNTemporaryLimitParameters
The com.rte_france.powsybl.iidm.export.adn.ADNTemporaryLimitParameters
class is used to model limit reductions for
temporary limits in a given duration range (inclusive).
Optional properties
maxDuration
The maxDuration
property is an optional property that defines the upper bound of the [minDuration, maxDuration] range.
The default value of this property is Integer.MAX_VALUE
.
minDuration
The minDuration
property is an optional property that defines the lower bound of the [minDuration, maxDuration] range.
The default value of this property is 0.
reduction
THe reduction
property is an optional property that defines the limit reduction for temporary limits. The default
value of this property is 1 (e.g. 100%).